Telecom Shutdown System

One Werkz Engineering  provide  OMTS- Telecom shutdown system based  on  Motorola  Solutions radio equipment. The product is highly configurable and absolutely  matches with the FPSO/ LNG tankers operational requirements. 

 
 
OMTS1.png

Description

Emergency Shutdown system (ESD) is to be initiated from the condensate taker to the FLNG or FPSO and shall carried out by dedicated UHF Link. Design as per different customer requirement, we provide fail safe design and redundancy design.

We programmed the SAFE/ EX handheld radios suited for explosive areas (ATEX)and a fixed base radio combined with a RTU remote  terminal unit to run the functional logic of the ESD feature to  stop the transfer pump in case of an emergency shutdown

 
OMTS2.png

Features

Alarm logging

The system is fully configurable to ignore sections or permanently shut down sections, the alarms and events are logged and displayed in a central operator panel.

Fail safe operation

ESD system has a fail safe operation mode. Should anything happen to parts of the system or the link to the alarm system be broken, the system will automatically go in shutdown mode.

HMI

2D panel to monitor the transfer operations. Different status likes alarm also can display on this 2D panel. 2D panel can be tablet or monitor (big screen). Alternatively, hardware panel using LED light also possible. 

Redundancy

To provide redundancy, all panels allow for manual operation in addition to operation from a central operator panel. All component provide hardware 1+1 redundancy